Twfta Marketplace
Application
The cables are used as cabling wires for the relays and electronic equipments in the Traffi c Control Center and Trackside Equipment Shelter. The CV cables are suitable for use only in Optical Control Panel (OCP) wiring.

Standards
•SNCF CT 500

Construction
Conductors
Class 5 stranded tinned copper (for flexible wires CV-S & CVZ-S type), class 1 solid tinned copper (for stiff wires CV & CVZ), 0.5/1.0/2.5/6.0 mm² cross section.

Insulation
White (for CVZ type)/coloured (for CV type) unleaded PVC

Sheath
Coloured polyamide outer sheath (for CVZ & CVZ-S type).

Electrical Characteristics at 20℃

CV/CVZ

Nominal Conductor Diameter mm 0.8 1.17 1.78
Nominal Cross Section Area mm² 0.5 1.0 2.5
Maximum Conductor Resistance(DC) Ω/km 36.1 17.9 7.56
Operating Voltage V 750

CV-S/CVZ-S

No of Strands/ Strand Diameter No/mm 16/0.2 32/0.2 50/0.25 84/0.3
Nominal Cross Section Area mm² 0.5 1.0 2.5 6
Maximum Conductor Resistance (DC) Ω/km 40.1 20.0 8.21 3.39
Operating Voltage V 750

Mechanical and Thermal Properties

Minimum Bending Radius (static): 4×OD (for fl exible wire); 5×OD (for stiff wire)
Minimum Bending Radius (dynamic): 8×OD (for fl exible
Coaxial Cable, Outdoor Telephone Cable, British Standard Control Cable, Elastomeric Cable, Fire Resistant Cables, PVC Insulated & Sheathed Unarmoured Cables, Railway Cable, Rolling Stock Cable, Railway Points Heating Cable, Instrumentation Cable
Contact Information:
TEL:
Fax:
Country:
China
Address:
Send Inquiry
Company:
Contact:
Email:
URL:
TEL:
Fax:
Country:
Address:
Subject:
Comment:

Products:

CV /CVZ Indoor Equipment Cables/Railway Cables
CV /CVZ Indoor Equipment Cables/Railway Cables, CV /CVZ Indoor Equipment Cables/Railway Cables,Application The cables are used as cabling wires for the relays and electronic equipments in the Traffi c Control Center and Trackside Equipment Shelter. The CV cables are suitable for use only in Optical Control Panel (OCP) wiring. Standards •SNCF CT 500 Construction Conductors Class...
UL 1107 Coaxial Cable
UL 1107 Coaxial Cable, UL 1107 Coaxial Cable,Conductor: Annealed Copper Wire (Bare Single,Bare Strand or Tinned Strand) Insulation: PVC (Polyvinyl Chloride) Braid shield: Annealed Copper Wire (Bare or Tinned Copper) Sheath: PVC ( Polyvinyl Chloride) Structure: Conductor Insulation Braid Shield...
UL 1107 Coaxial Cable
UL 1107 Coaxial Cable, UL 1107 Coaxial Cable,Conductor: Annealed Copper Wire (Bare Single,Bare Strand or Tinned Strand) Insulation: PVC (Polyvinyl Chloride) Braid shield: Annealed Copper Wire (Bare or Tinned Copper) Sheath: PVC ( Polyvinyl Chloride) Structure: Conductor Insulation Braid Shield...
UL 1107 Coaxial Cable
UL 1107 Coaxial Cable, UL 1107 Coaxial Cable,Conductor: Annealed Copper Wire (Bare Single,Bare Strand or Tinned Strand) Insulation: PVC (Polyvinyl Chloride) Braid shield: Annealed Copper Wire (Bare or Tinned Copper) Sheath: PVC ( Polyvinyl Chloride) Structure: Conductor Insulation Braid Shield...