Twfta Marketplace
Products Companies Find Suppliers Find buyer
 
HV power transmitting , transforming equipment,insulation power factor testing transformer,special transformer,DC HV power generator,automatic testing board with the feature of transformer,H.V.transformer&electrical network warning device around the jails and electrical measuring instrument  

 
  Company Profile
  Products Showroom
  Contact Us
 




 

Lightning impact peak Ammeter




        Inquiry   Now      
        Contact   Info       
   
   


Type Impulse Peak-Current Meter
Used for measuring any once –impulse full waves whose first signal form’s length overpass 500ns ,also measuring and storing the numerical value of the impulse peak-voltage , peak-current and other once-impulse peaks. A circuit that protects a computer system from dangerously high voltage surges. The whole design is adopted with industry standards。
Input voltage: :≤±1600V
Input resistance :2MΩ//39PF
Measuring accuracy :1%
Time for rise:About 85ns
Work environment: 0~70℃,0~95%
Voltage ratio setting:0.1~9999.9
Range of display:0~16000KV
Connection: parallel input with two outlets




China,Wuhan GuoDian HuaRui Power TestTechnology Co.,Ltd. Products

Lightning impact peak Ammeter
Type Impulse Peak-Current Meter Used for measuring any once –impulse full waves whose first signal form’s length overpass 500ns ,also measuring and storing the numerical value of the impulse peak-voltage , peak-current and other once-impulse peaks. A circuit that protects a computer...,Lightning impact peak Ammeter, peak Ammeter
 
Vacuum switch vacuum tester
Type Vacuity of the Vacuum Switch Measuring Instrument This instrument is made by adopting the latest excitability flexible circuit conductor to measuring the vacuity of the vacuum switch automatically without the unloading. The operation is simply and reliable. It can be used in many...,Vacuum switch vacuum tester , Vacuum switch
 
Insulation oil and gas chromatography analyzer
Insulation Oil Gas Chromatographic Analyzer Technical parameter: 1. Column compartment temperature:room temperature +15℃~350℃,controlling temperature range: ±0.1~0.2℃ 2. Testing room temperature: room temperature+30℃~350℃, controlling temperature range: ±0.1~0.2℃...,Insulation oil and gas chromatography analyzer , Insulation oil
 
High voltage switch dynamic characteristics test instrument
High Voltage Switch Mechanical Features Tester This tester is used to measure time, speed and process of the overstuffed, oil-minimum breaker, vacuum and SF6 high voltage switch and high-voltage circuit breaker. It is also can be used to measure the closing and trip time, the bounce...,High voltage switch dynamic characteristics test instrument , High voltage switch
 
Standards current transformer
precision standard current transformer The standard current transformer used to verify the 0.01 level the following current transformer. The standard current transformer is a winding, secondary windings. Features: Users can specify criteria on the nameplate current ratio for...,Standards current transformer , transformer
 
Transformers OLTC Tester
Type On-Load Tapping Changing Switch of Transformer Tester This type of tester is used to measure and analyze the electric property of the on-load tap-changer of power transformer. It can measure the parameters automatically. The parameters include the transient time, the transient...,Transformers OLTC Tester , Transformers
 
type of high pressure jer phase detectors
type of high pressure jer phase detectors Power system check phase is a regular work. The traditional fixed phase method adopts high voltage PT or high-pressure check appliances, the former equipment cumbersome and high-voltage lead down to PT very insecure, which depends on is faint glow...,type of high pressure jer phase detectors, jer phase detectors
 
Standard voltage transformer
precision standard voltage transformer This equipment is mainly for primary power supply and the actual needs of the production sector carefully designed and manufactured, the company provides inflatable voltage standard transformer, standard voltage oil-immersed transformer, dry...,Standard voltage transformer , transformer
 
Phase of the frequent rate
Industrial Frequency Phase Meter The main technical indexes Measuring method of phase: either two lines U-U、U-I、I-I Measuring precision of phase: 0.2 grade U(U-I method), 10mA~10A divided into 4 grades I(on-line detaction100mA~5A) Resolution:0.1°,0~360° Range of...,Phase of the frequent rate , frequent rate
 
Series Electric columnar regulator / adjustable power supply
Series of Electrical Plunger Voltage Regulator Introduction: It is a kind of contact ratio autotransformer which can adjust load voltage within rated voltage. This series of products are well designed because they adopt UK imported A brush for voltage adjusting parts. With strict...,Series Electric columnar regulator / adjustable power supply , Voltage Regulator
 
Harmonic power (power quality) measurement
Series of HRDXC Testing, Alarming and Analyzing Instruments of Electric Harmonic It meets the whole requirements of GB/T1459~93 to test the virtual value, and positive ,reverse and zero sequence component of current and voltage Measuring area: content of voltage harmonic, distortion...,Harmonic power (power quality) measurement , Harmonic power
 
 
Contact Info
URL:
TEL:
Fax:
Country: China
Address:
Wuhan,Wujiashan Taiwanese investment zones(San Dian),Xinchengda Optical Science and Technology Industrial Park, GuoDian Huarui Building,Wuhan,China

Send Inquiry

 
Company:
*Contact:
*Email:
URL:
TEL:
Fax:
Country:
Address:
*Subject:
Comment:
 

 
 
 
  Contact Us Site Map About Us Trade Links
2005-2014 copyright by twfta.com. All rights reserved.