Current Transformer site tester calibration device




        Inquiry   Now      
        Contact   Info       
   
   


current transformer field tester
Features
Instrument adopts platform interface technology, large-screen LCD, all Chinese hints of automatic measurement, the whole process simple instrument operation, Equipment is small in size, easy to carry, only a few people can be fast do measurement, In this company integrated litres of flow, pressor device with the cooperation of choose and buy equipment, and can be made with the current transformer protection the volt-ampere characteristics and 10% error curve tests. Operating process convenient, and automatic display volt-ampere characteristics curve and draw a 10% error curve, The instrument can be of voltage transformer for qualitative measurements: when measuring instrument at the voltage transformer, the primary side add certain power frequency voltage, can measure one times voltage and second induced voltage, it is concluded that the voltage transformer in this BiCha voltages and Angle poor. The instrument to measure the current and voltage transformer field second load, measurable the load of the current transformer BiCha and Angle poor. This device can measure no logo of current transformer or change of voltage transformer, and measured accurately than fast, stable performance is good, no need for additional liters flow or pressor sources, This device can measure current transformer 5% ~ between arbitrary point of 120% BiCha and angular, without standard current transformer and external liters flow sensor, the accuracy of the measurement to meet the technical index requirements, suitable for on-site tests use; Instrument can undertake various measurement data storage and print, various parameters power lost can save.
Technical parameters
Current transformer measurement range:5A/5A~5000A/5A(5A/1A~4000A/1A)
Voltage transformer measurement range:2.2kV~132kV
The actual secondary stress test:PT load 10VA ~ 500VA Measurement error: 2nd level
CT load 0.1 Ω ~ 25 Ω Measurement error: 2nd level
Volt-ampere characteristics testing
Current test range: 0.1A~50A Measurement error: 1st level
Voltage test range: 10V ~ 1500V Measurement error: 1st level
Working conditions: power supply voltage: AC 220V + 10%
Power frequency: 50Hz + 2% Environmental temperature (0 ~ 40 ° C)
25 ° C environment humidity: when < 85%




China,Wuhan GuoDian HuaRui Power TestTechnology Co.,Ltd. Products

Current Transformer site tester calibration device
current transformer field tester Features Instrument adopts platform interface technology, large-screen LCD, all Chinese hints of automatic measurement, the whole process simple instrument operation, Equipment is small in size, easy to carry, only a few people can be fast do measurement,...,Current Transformer site tester calibration device, Transformer
 
Insulated boots (gloves) pressure testing device
type insulating boots (gloves) withstand test device Brief introduction HRJNY type insulating boots (gloves) withstand test device is according to the company insulation boots (gloves) test procedures and follow the masses of users advice which is to design and manufacture. This product...,Insulated boots (gloves) pressure testing device, Insulated boots
 
Quick test for DC Resistance (1 A-80A)
Fast DC Resistance Tester It is used for testing DC resistances of transformers, motors, instrument transformers and other equipments’ (the speed of the test is fast, the results can be showed and printed) The main technical indexes: Measurement accuracy:±0.2%...,Quick test for DC Resistance (1 A-80A) , Resistance
 
Lightning impact of current generator testing
Series of Experimental Instruments for the Impulse Current Generator Arranged in Star-shaped and straight lines forming 6 standardized impulse waveforms Rated current:5-200kA Square wave current:2000A Rated capability:50-240kJ Capacitance:8-12 Rated voltage:0-120kv ,Lightning impact of current generator testing, impact current generator
 
Measuring absorption ratio and polarization index insulation resistance tester
Series of Megohm-meter (Insulated Resistance Meter) It is applicable for testing the in insulated resistance of all kinds of transformer, generator, cable, switch, and electric devices. The design of low-watt-loss and electrostatic-proof makes the outdoor operating possible....,Measuring absorption ratio and polarization index insulation resistance tester , resistance
 
Digital insulation resistance tester
Series of Megohm-meter (Insulated Resistance Meter) It is applicable for testing the in insulated resistance of all kinds of transformer, generator, cable, switch, and electric devices. The design of low-watt-loss and electrostatic-proof makes the outdoor operating possible....,Digital insulation resistance tester , resistance
 
Automatic CT / PT voltammetry of change than the Comprehensive test
CT - PT automatic transformer volt-ampere characteristics radiocomm.tester Features a) Automatic type tester only digital setting, set the highest test voltage, the maximum current and step length, the device will automatically from zero pressor gradually. Can automatic testing ground will...,Automatic CT / PT voltammetry of change than the Comprehensive test , voltammetry
 
Intelligent Transformer empty load loss tester
Type Special Intelligent Tester for Power Transformer Loss This type of test set is used for monitoring the actual qualities of the off the line and the ongoing power transformers. It can be the spot test for the unloaded and loaded loss characteristic of the transformers. At the same...,Intelligent Transformer empty load loss tester , Transformer
 
Contacts (circuit) resistance tester
Loop (Contacting) Resistance Tester The gear is used to test the contact resistance and loop resistance of the switch controlling equipments, adopting the national standard GB763 direct current DC 100A(120A/150A). It has accurate testing, stable performance and the capability of...,Contacts (circuit) resistance tester , resistance
 
Automatic variable than the group Tester
Type Automatic Transformation Ratio Test Equipment This type of equipment can be used to test the transformation ratio, the polarity, the bracket and the inaccuracy of the single-phase or three phase transformers. The key technical indexes: The measuring range of the transformation...,Automatic variable than the group Tester , Transformation Ratio
 
Power harmonic meter
Series of HRDXC Testing, Alarming and Analyzing Instruments of Electric Harmonic It meets the whole requirements of GB/T1459~93 to test the virtual value, and positive ,reverse and zero sequence component of current and voltage Measuring area: content of voltage harmonic,...,Power harmonic meter , Power harmonic
 
 
Contact Info
URL:
TEL:
Fax:
Country: China
Address:
Wuhan,Wujiashan Taiwanese investment zones(San Dian),Xinchengda Optical Science and Technology Industrial Park, GuoDian Huarui Building,Wuhan,China

Send Inquiry

 
Company:
*Contact:
*Email:
URL:
TEL:
Fax:
Country:
Address:
*Subject:
Comment:
 

 
 
 
  Contact Us Site Map About Us Trade Links
2005-2013 copyright by twfta.com. All rights reserved.